The Determination of Recommended Concentration of Outdoor PM10 in the Calculation of Filter Selection

发布时间:2024-08-09
点击次数:
所属单位:
建筑设备科学与工程学院
发表刊物:
EPPH-iCBBE2010
关键字:
中文关键字:过滤器;PM10;空调;室内空气,英文关键字:filter; PM10; atmosphere; air conditioning; indoor
摘要:
In the paper, the concentration of outdoor PM10 in more than 20 provinces in recent years is analyzed. It aims at providing a theoretical foundation for the calculation of filter selection in the air-conditioning system. By collecting data and curve fitting, the recommended concentration of PM10 in the design of air-conditioning is determined. The results show that: during the calculation of filter selection, firstly, for the airconditioning system running in the whole year, the recommended mean concentration of outdoor PM10 is between 0.08 and 0.12mg/m3; secondly, for those air-conditioning system which is running only in the air-conditioning season (from May to September), it is between 0.07 and 0.09mg/m3.