Developing In-Situ Permeability and Air Voids Requirements for Open-Graded Friction Course Pavement: Case Study
 
                    
                   
                            
                              - Release time:2024-08-09
 
                              
                                - Hits:
 
                            
                     
                    
                    
                      
                        
                             -     
 
                             -     
 
                             -    
Affiliation of Author(s): 
土木工程学院   
                             -     
 
                             -    
Journal: 
International Journal of Civil Engineering   
                             -     
 
                             -     
 
                             -    
Key Words: 
Open-graded friction courseIn-situ permeabilityVolumetricUltimate drainage capacityRainfall intensity   
                             -    
Abstract: 
Open-graded friction course (OGFC) is a functional mixture used in high-intensity rainfall areas where there exists a risk of flash flooding. To ensure its functionality, there is a need to specify the minimum volumetric requirements on the OGFC mixture. This study aimed at developing in-situ permeability and interconnected air voids content requirements for an OGFC pavement under various rainfall intensities. Seven air voids contents (16%, 17%, 18%, 19%, 20%, 21%, and 22%) of OGFC slab specimens were prepared in the laboratory, and volumetric properties (interconnected air voids and total air voids content) and hydraulic conductivities (permeability coefficient) were characterized. A rainfall simulator was developed to quantify the ultimate drainage capacities of OGFC mixtures under simulated rainfall events. It was found that the OGFC mixture with a higher designed air voids content exhibited a higher permeability coefficient and ultimate drainage capacity. However, the in-situ drainage capacity of an OGFC pavement was affected by the number and width of lanes. Based on a field project that was two-way eight-lane, 2% cross slope, 20% air voids content, and 5-cm thick OGFC, the minimum in-situ permeability coefficient was determined as 825 mL/15 s. It was recommended to integrate design factors such as number and width lanes, and local rainfall intensity into the OGFC pavement design process to achieve desirable in-situ drainage functionality.   
                             -     
 
                             -     
 
                             -    
First Author: 
liuli   
                             -    
Indexed by: 
Journal paper   
                             -     
 
                             -     
 
                             -     
 
                             -     
 
                             -     
 
                             -     
 
                             -     
 
                             -     
 
                             -     
 
                             -    
ISSN No.: 
1735-0522   
                             -    
Translation or Not: 
no   
                             -     
 
                             -    
Date of Publication: 
2021-07-14   
                             -     
 
                             -