EN

李勇

副教授   硕士生导师

个人信息 更多+
  • 教师拼音名称: Li Yong
  • 所在单位: 建筑设备科学与工程学院
  • 学历: 博士研究生
  • 性别: 男
  • 学位: 博士学位
  • 在职信息: 在职
  • 主要任职: 绿色建筑全国重点实验室能源利用中心

其他联系方式

邮箱:

论文成果

当前位置: 李勇 - 科学研究 - 论文成果

Impact of groundwater seepage on the thermal performance of pit thermal energy storage based on two-phase flow m

发布时间:2026-04-16
点击次数:
DOI码:
10.1016/j.enbuild.2025.116333
所属单位:
西安建筑科技大学
发表刊物:
Energy and Buildings
关键字:
Water pit thermal energy storage Two-phase flow model Porous media Heat loss Ground water
摘要:
Pit thermal energy storage (PTES) plays a significant role in the field of building energy utilization. Due to the direct contact between PTES and soil as well as the widespread presence of groundwater, the hydrogeological environment must be considered for its impact on its thermal performance. In particular, groundwater seepage alters heat transfer characteristics between PTES and soil, thereby significantly impacting the thermal storage efficiency of the system. This study conceptualized the soil domain as unsaturated soil and developed a model based on two-phase flow in porous media to simulate thermo-hydro interactions between groundwater and the system. The model was validated against operational data from the Dronninglund’s PTES. A parametric sensitivity analysis was conducted to elucidate the impact mechanisms of confined aquifer properties, including depth to the aquifer (6,9,14,25 m), thickness (10,15 m), flow velocity (5.4⋅10-6, 5.4⋅10-7, 1⋅10-7 m/s), and degree of saturation (0.3,0.45,0.9), on the thermal performance of PTES. Results indicate that the heat loss of PTES stabilized by fourth year under groundwater conditions, whereas stabilization occurs by seventh year without groundwater influence. Under dynamic groundwater conditions, the annual average thermal loss from the system increased by 69.24 % compared to scenarios without groundwater flow. The soil temperature field diffused along the groundwater flow direction, and the influence range of PTES expanded accordingly. Further analysis revealed differential impacts on PTES surfaces: thermal loss at the upstream surface increased by 131.9 % relative to static groundwater conditions, whereas the downstream surface exhibited only a 10.8 % increase. In addition, when the vertical separation between the aquifer and PTES base exceeded 10 m, thermal interaction attenuated significantly. These findings provide critical guidance for PTES site selection and engineering design.
第一作者:
Qingju Mou,Yanfeng Liu,Jianhua Fan
论文类型:
期刊论文
通讯作者:
Yong Li,Dengjia Wang
学科门类:
工学
文献类型:
J
卷号:
347
期号:
PartA
页面范围:
116333
ISSN号:
03787788
是否译文:
发表时间:
2025-01-01
收录刊物:
SCI、EI