Personal profile
教育背景: 2012/1,西安建筑科技大学,供热通风供燃气及空调工程,博士学位 1990/5,西安交通大学,化工过程机械,硕士学位 1987/7,西安交通大学,压缩机及制冷技术,学士学位 工作经历: 1990/5至今,西安建筑科技大学,环境与市政工程学院,历任讲师、副教授、教授 -2005/7-2005/8,日本九州大学,应用力学研究所,...
more+所属单位:建筑设备科学与工程学院
发表刊物:Energy and Buildings
关键字:HP-1 HTHP、Environmentally friendly refrigerant、Injection Characteristics、Performance analysis optimization、Decarbonization
摘要:In the context of low-GWP refrigerants becoming a research hotspot, the environmentally friendly refrigerant HP-1 with independent intellectual property rights in China has demonstrated significant advantages in fields such as data centers and 5G base stations. However, there are few applied studies in the field of high-temperature heat pumps (HTHPs), therefore, in this study, HP-1 was utilized in HTHP system and this process was combined with the injection technology. It has been proven to be an effective approach for performance improvement. The injection characteristics of HP-1-based HTHP were analyzed and optimized with a focus on safety, stability, and efficient operation. The application advantages of HP-1 were compared and analyzed in terms of thermodynamic performance and Total Equivalent Warming Impact. The results indicated that there were three types of characteristic injection pressures based on system performance, corresponding to the maximum coefficient of performance (COP), the lowest electronic expansion valve inlet refrigerant temperature, and the lowest exhaust temperature of the compressor. Further, the corresponding control equations for injection pressure were obtained. Based on the safety injection pressure, the optimal COP under injection pressure could effectively improve the COP of the system by 2.1–5.2 %, and the exhaust temperature also increased by 6.1–10.1 %. When the temperature of the heat source was 50 ◦C and the target heating temperature was 120 ◦C, the heating capacity of HP-1 increased by 10.8 % compared with that of R245fa, the COP of the system increased by 2.7 %, and the volume heating capacity increased by 10.3 %. Moreover, the emission reduction effect of HP-1 was significant, and the carbon dioxide emissions were reduced by 15.4–39.1 %. The analysis shows that HP-1 exhibits better performance and environmental characteristics than HFC-245fa. This study is of guiding significance to improve the thermodynamic performance of HTHP, for the safe and efficient operation and energy saving and emission reduction in the industrial field.
第一作者:南晓红
论文类型:期刊论文
卷号:303/13799
ISSN号:0378-7788
是否译文:否
发表时间:2023-11-25
版权所有:西安建筑科技大学 | 站点维护:网络与信息化管理处