Study on corroded detection of bridge prestressed reinforcement based on the magnetic flux leakage method
发布时间:2024-08-09
点击次数:
- 所属单位:
- 土木工程学院
- 发表刊物:
- Advanced Materials Research
- 关键字:
- 中文关键字:腐蚀预应力筋;磁漏法(MFL);非破坏性测试(NDT),英文关键字:Corroded Prestressed Reinforcement; Magnetic Flux
- 摘要:
- As the pretressed reinforcement of prestressed concrete structure leads to rust, it would bring serious disadvantage effect to load capacity of the concrete members and reduce the reliability of all concrete structure greatly more than that of ordinary steel caused. If the prestressed reinforcement can be detected in time, the prestressed concrete structure would be got effective maintenance. In the paper, magnetic leakage testing method used in ordinary steel detection is applied to test the simulation corrosion bug of the prestressed reinforcement in bridge with nondestructive mode. The result of experiment indicates that in the distance of 100 mm from the concrete surface the magnetic leakage testing method can detect effectively the loss ratio of cross-section more than 20 percent of a hank of prestressed strands caused by a part of prestressed strands corroded to break. At last, the paper also puts forward the experiment problems in existence and the improvement methods.
- 备注:
- 牛荻涛
- 第一作者:
- 牛荻涛,赵珺
- 论文类型:
- 期刊论文
- 卷号:
- 卷:105-107
- 期号:
- 期:
- 页面范围:
- 页:1241-1244
- 是否译文:
- 否
- 发表时间:
- 2012-06-01
- 上一条:连续梁桥的零号块应力分析
- 下一条:钢筋混凝土桥梁锈胀开裂时间模型敏感性分析